1000kva 500kva 3-phase Pad Mounted Transformer
These transformers are installed at ground level on concrete pads, hence their name. They are strategically placed close to buildings or along streets to minimize power loss over long distribution lines. Their location ensures efficient power distribution and ease of maintenance.
Power Rating |
45kVA~6000kVA |
Primary Voltage Ratings |
up to 35kV |
Secondary Voltage Ratings |
up to 24.94kV |
H.V. Tap Range |
±2×2.5% or others |
Connection Type |
Delta/Wye |
Winding Conductor |
Copper or Aluminum |
TYPE |
Loop feed / Radial feed |
Configuration |
Live front / dead front |
BIL |
30-150kV |
Standards |
ANSI, IEEE, DOE, CSA, NEMA, UL |
Application |
Residential Areas, Hotels, Single Family Houses, Parks, Distribution Systems |
Oil Type |
Mineral Oil or Biodegradable Natural Vegetable Oil, Non PCB Fluid |
Finish Color |
Bell Green or as customized |
Enclosure Rating |
NEMA 3R Weatherproof Wiring Cabinet, Sealed Tank |
Transformer Tank: Made of steel, it houses the core and windings.
Transformer Core: Provides a path for magnetic flux.
Transformer Windings: Copper or aluminum conductors wrapped around the core.
Bushings: Insulating devices for electrical connections.
Tap Changer: Adjusts output voltage as needed.
Insulating Oil: Provides insulation and cooling.
Gauges: Measures parameters like oil temperature and pressure
Lifting Lugs: Used for transportation.
Grounding Terminals: Ensures electrical safety.
Nameplate: Displays essential information.
Loadbreak Switch: Allows for the safe interruption of current flow during maintenance or repairs.
Fuses: Protects against overcurrent conditions by melting when the current exceeds a certain threshold.
The following table is the standard parameter of the 1000kva 500kva 3-phase Pad Mounted Transformer. If you need other capacity and voltage levels, please contact the TRANSpower to obtain accurate technical parameters and offers.
We provide customized three phase pad mounted transformers according to customers.
Below Specs Are For Reference ONLY .
Three Phase Pad Mount Transformers Sizes |
||||||
kVA |
Type |
HV |
LV |
W(mm) |
D(mm) |
H(mm) |
75 |
radial |
25000Delta |
480GrdY/277 |
1280 |
1085 |
1085 |
150 |
loop |
14400v |
600GrdY/347 |
1480 |
1250 |
1750 |
225 |
radial |
4160Delta |
347GrdY/600V |
1480 |
1295 |
1750 |
300 |
loop |
345000 |
208GrdY/120 |
1500 |
1730 |
1850 |
500 |
loop |
1247Grdy/7200V |
600Y/347 |
1447 |
1800 |
1750 |
750 |
radial |
24940GrdY/14400 |
800GrdY/462 |
1485 |
1730 |
1750 |
1,000 |
radial |
249400DELTA |
480V |
1730 |
1350 |
1850 |
1,250 |
loop |
25000V |
416V |
1730 |
1320 |
1920 |
1,500 |
loop |
4160GRDY/2400 |
600GrdY/347 |
1730 |
1910 |
1965 |
1,500 |
loop |
34500DELTA |
480GrdY/277 |
2220 |
2069 |
2065 |
1,750 |
loop |
13800Delta |
480GrdY/277 |
1730 |
2304 |
1900 |
2,000 |
radial |
4160DELTA |
415GrdY/240 |
1730 |
1950 |
1810 |
2,500 |
loop |
25000DELTA |
600GrdY/347 |
1730 |
2560 |
1960 |
2,550 |
loop |
12470DELTA |
415GrdY/240 |
1730 |
2000 |
2200 |
2600 |
Loop |
34500DELTA |
416GrdY/240 |
1730 |
1695 |
2290 |
3000 |
Loop |
27,600DELTA |
13,800DELTA |
1830 |
2360 |
2000 |
4000 |
loop |
27600Delta |
600GrdY/347 |
1900 |
2500 |
2010 |
5000 |
radial |
13,800DELTA |
4,160GrdY/2,400 |
1900 |
2735 |
2500 |
7000 |
loop |
27,600DELTA |
13,800DELTA |
2200 |
3030 |
2080 |
7500 |
loop |
249400DELTA |
4.16kv Wye |
2300 |
3200 |
2100 |
10000 |
loop |
24900GrdY/14400 |
600V |
2800 |
3500 |
2560 |
After each unit of Pad mounted transformer manufactured, routine tests/FAT will be carried out by the requirements of ANSI/IEEE C57.12.90 and C57.12.00. The test report comply with IEEE/CSA standards, and efficiency comply with DOE 2016 Standards.
Routing Test in Our Factory
Winding Resistance Test
Insulation Resistance Test
Voltage Ratio Error Test
Short-circuit Impedance Test
No-load Loss (Wattage) Test
Load Loss (Wattage) Test
Induced Voltage Withstand Test
Separate Source Voltage Withstand Test
Pressure Integrity Test Test
We offer both online and offline test supervision options for our customers. You can also choose a third party, such as SGS, CSA, or UL to visit Transpower's factory, during the witness test, the test being executed and receive a report that fully comply with standard requirements. Alternatively, you can request online video monitoring to observe the testing process in real-time. Ensuring transparency and confidence in the testing procedures.
Our production and testing equipment have professional calibration every year.



Assembly and Packaging Area


After Assembled then Shipping by container


Our Three Phase Pad Mount Transformers can be used in variety of applications, all ranging in complexity.
Q: What Is The Difference Between Loop Feed And Radial Feed?
Q: What is the difference between a delta and wye connection in transformers?
Wye Connection: The windings connect to a common point (neutral), providing a stable voltage supply. It's often used for lighting and small equipment.
http://www.trans-elec.com/